ACM8
ACM8
unit converts one (1) 12 to 24 volt AC or DC input into eight (8)
independently controlled fuse protected outputs. These power outputs
can be converted to dry form "C" contacts. Outputs are activated by an
open collector sink or normally open (NO) dry trigger input from an
Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The
unit will route power to a variety of access control hardware devices
including Mag Locks, Electric Strikes, Magnetic Door Holders, etc.
Outputs will operate in both Fail-Safe and/or Fail-Secure modes. The
unit is designed to be powered by one common power source which will
provide power for both the board operation and locking devices, or two
(2) totally independent power sources, one (1) providing power for
board operation and the other for lock / accessory power. The FACP
Interface enables Emergency Egress, Alarm Monitoring, or may be used to
trigger other auxiliary devices. The fire alarm disconnect feature is
individually selectable for any or all of the eight (8) outputs. |
| |
• UL Recognized Component for Access Control Systems (UL294).
File# BP6714.
• 12 to 24 volt AC or DC operation (setting not required).
• Power Supply Input Options:
- One (1) common power input (board and lock power).
- Two (2) isolated power inputs (one (1) for board power and
one (1) for lock/hardware power).
• Eight (8) Access Control System outputs.
- Eight (8) fuse protected Fail-Safe and/or Fail-Secure 12VDC power outputs.
- Any power output may be converted to dry form "C" relay output.
- Eight (8) fuse protected 12VDC auxiliary power outputs (unswitched).
• Red LEDs indicate outputs are triggered (relays energized).
• Eight (8) Access Control System trigger inputs.
- Eight (8) normally open (NO) inputs.
- Eight (8) open collector inputs.
- Any combination of the above.
• Fire Alarm Disconnect:
- Fire Alarm Disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
- Normally open (NO) or normally closed (NC) dry contact input.
- Polarity reversal input FACP signaling circuit.
• Fire Alarm trigger LED indicates that the Fire Alarm Disconnect has been activated.
• Fire Alarm output relay for triggering auxiliary reporting devices (form "C" contact rated @ 1 amp 28VDC). • Lifetime Warranty.
• Dimensions (approximate): 4.5”W x 8”L x 1.25”H |
|
|
|
|
|